Ultra High Performance Liquid Chromatograph LPGS

Availablity: In stock

Catalog/Part Number: Quaternary System
Brand: SHIMADZU
Supplier: SHIMADZU
Supplier Location: JAPAN
Inventory Weight: 75 kg
Unit of Measurement:
Inventory Brochure: C190E168.pdf |

Catalog/Part Number:: Quaternary System

Sorry no inventory found for this brand at this time.

Description

The Nexera Quaternary System can be configured to include two solvent delivery units in combination with a low-pressure unit. Four types of mobile phases can be configured for each solvent delivery unit, resulting in a total of eight mobile phase types. This provides the flexibility to investigate up to 16 mobile phase combinations. Significant improvements in method development efficiency means users have more time to focus on other critical activities. The product range includes the Nexera Method Scouting System, which contains six columns and automates the method development process by automatically switching the column and mobile phase combinations. The Nexera Quaternary System not only provides the optimal system for HPLC/UHPLC method development but can be widely used for routine HPLC analysis. It continues the tradition of robust, reliable ultra-high performance.

Efficient method development with up to 16 mobile phase combinations

Seamless method transfer from conventional HPLC to UHPLC

Highly accurate solvent delivery ensures reliable analysis

Expandable to Nexera Method Scouting System for automated method development processing


https://shimadzugroup.sharepoint.com/sites/gcs/an_sales/Literature/Distributor/Chromatography/LC/C190E168.pdf

Catalog/Part Number: Quaternary System Category:

Technical Specifications


System volume
40 µL (when using small-volume piping)
Maximum operating pressure

130 MPa (3.0 mL/min max.)

80 MPa (3.0001 to 5.0 mL/min)

22 MPa (5.0001 to 10.0 mL/min)

Settable flow rate range
0.0001–10.0000 mL/min (in 0.0001 mL/min step)
Number of loaded mobile phases
4 solvents max. for each solvent delivery unit)
Gradient type
Low-pressure gradient
Flow rate accuracy 
±1.0% (under specified conditions)
Concentration accuracy
±0.5% (under specified conditions)
Injection volume range 
0.1 to 10.0 µL (in 0.1 µL step), 10 to 50 µL (in 1 µL step)
Injection volume accuracy
±1.0% (total volume injection method, under specified conditions)
Needle cleaning
Set as required before and after sample injection. Cleans exterior and interior of needle. Max. 4 solutions

https://shimadzugroup.sharepoint.com/sites/gcs/an_sales/Literature/Distributor/Chromatography/LC/C190E168.pdf

Add a review

You must login to make reviewLogin

  1. Zero(0) Reviews