Description
Redesigned constant temperature bath for freezing point determinations on fuel samples at temperatures as low as –100°F (–73°C). Accommodates K29700 Freezing Point Apparatus and accessory stirrer. Microprocessor PID circuitry provides precise, reliable temperature control within ASTM specified tolerances. Simple push button controls and dual digital displays permit easy setting and monitoring of bath temperature. Bath medium is contained in a clear, evacuated Dewar flask, and glare-free fluorescent back lighting provides excellent visibility when working with the freezing point samples. Air-cooled hermetic compressors provide efficient operation with the use of CFC-free refrigerants. Temperature control uniformity is assured by means of a motorized stirrer which provides complete circulation without turbulence. Cabinet construction is polyester-epoxy finished steel with a chemical-resistant composite top surface. Working (top) surface includes port and mounting plate for K29700 Freezing Point Apparatus and accessory stirrer. Bath rests on adjustable leveling feet.
TEST METHOD:
The freezing point of an aviation fuel is the lowest temperature at which the fuel remains free of solid hydrocarbon crystals that can restrict the flow of fuel. The temperature of the fuel in the aircraft tank normally falls during flight depending upon aircraft speed, altitude, and flight duration. The freezing point of the fuel must be lower than the minimum operational tank temperature. The test determines the temperature below which solid hydrocarbon crystals form in aviation fuels. The sample is cooled with continuous stirring in a Dewar-type sample tube until crystals appear.
FEATURES:
Improved
design with enhanced performance and safety features
Operating
range to –100°F (–73°C)
Microprocessor
PID digital temperature control
Dual digital
displays show set point and actual bath temperature
Selectable
temperature scale – Fahrenheit or Celsius
Conforms to
ASTM D2386 and related specifications.
Technical Specifications
Conforms to
the specifications of:
ASTM D2386; IP
16; ISO 3013; DIN 51421; FTM 791-1411; NF M 07-048
Temperature
Range: Ambient to –100°F (–73°C)
Temperature
Control Accuracy and Uniformity: Exceeds ASTM requirements throughout the
operating range
Display: 0.1°C/°F resolution.
ELECTRICAL REQUIREMENT:
115V, 60Hz,
Single Phase, 18.3A
220-240V,
50Hz, Single Phase, 10.0A
220-240V, 60Hz, Single Phase, 10.0A.
Shipping
Weight: 470 lbs (213.2 kg)
Dimensions:
41x35x38 in. (104.1x88.9x96.5 cm)