Automatic Cold Filter Plugging Point Analyzer with Touch Screen
Catalog/Part Number:: KLA-4-TS/2
Description
The cold filter plugging point detection system provides automated
sample testing with the accuracy and repeatability in accordance with ASTM
D6371 and related international test methods. The sample is cooled according to
the pre-selected temperature profile. A 20 mBar vacuum is applied to the sample
at specific intervals across a 45 micron mesh filter into the aspiration glass
cell assembly. If it takes more than 60 seconds for the sample to reach the
upper barrier detector or more than 60 seconds to return below the detector
upon release, then the test is complete and the cold filter plugging point has
been reached.
Integrated Panel PC and Software Package–The Automated Cold Filter
Plugging Point Analyzer is a complete standalone system featuring an integrated
panel PC with an advanced software package. The 6.4” TFT/LCD touch screen
display has a resolution of 640x480 with a 262K color scheme. All analytical
parameters are graphed and displayed in real time as well as recorded in
Microsoft® Excel compatible file format. The software monitors the operation
and performance of all the analyzer components for proper data measurement,
including the solenoid valves, cooling system, pressure sensors, and the
Platinum resistance PT100 Class A temperature probe. Cooling System–For various user applications,
the automated cold filter pluggin point system is available with either
one-stage cooling for temperatures as low as -45°C or two-stage cooling for
temperatures as low as -80°C. The direct cooling system features integrated gas
CFC free motors compressors thus eliminating the need for a solvent cooling
bath. The direct system is capable of rapid cooling, approaching -80°C bath
temperatures in approximately 15 minutes, and utilizes less electricity than
standard cooling systems. The rapid cooling feature combined with a consistent
cooling profile system provides repeatable results with high test
reproducibility.
Vacuum System–The automated cold filter plugging point analyzer
can be configured with either an internal or external vacuum generator. The
internal vacuum generator provides a smaller footprint for the complete CFPP
system and consists of a 350 mBar micro-pump and an electronic pressure/vacuum
regulator composed of a proportional valve, pressure/vacuum control sensor,
regulator for reference vacuum generation at 20 mBar and a vacuum stabilizer.
The external vacuum generator includes a vacuum pump, two glass bottles and a
glass cork with a U-tube, funnel and manual flow regulating valve.
TEST METHOD:
Determines the highest temperature at which a given volume of diesel, biodiesel or heating fuel fails to pass through a standardized wire mesh filtration device in a specified time when cooled under specified conditions. The Cold Filter Plugging Point (CFPP) of a fuel is suitable for estimating the lowest temperature at which a fuel will give trouble-free flow in certain fuel systems.
FEATURES:
Conforms to ASTM D6371 and related specifications
Standalone system with Integrated Touch Screen Panel PC
Direct Cooling system eliminates the need for solvent cooling
baths
One-stage cooling system provides temperatures as low as -45°C and
a two-stage cooling system down to -80°C
Option of internal or external vacuum generation system Safety
Features
Audible alarm and displayed messages (at the end of the analysis
and in case of errors and/or malfunctions)
Pressure controller for 1st and 2nd stage motor compressor
Thermostat for 2nd stage activation
Thermo-switch for each cooling / heating jacket
Motor compressors equipped with internal overload devices.
ACCESSORIES:
Calibrated Aspiration Pipette complete with Filter Kit for CFPP
Cord Cable without plug
Calibrated Test Jar
User Manual
Connection Tube for Vacuum System Operating Software
Spacer
Technical Specifications
Conforms to the specifications of: ASTM D6371; IP 309, 419; EN 116
Temperature Range: One-Stage: +60 to -45°C Two-Stage: +60 to -80°C
Resolution: 0.06°C Accuracy: ±0.1°C
Repeatability / Reproducibility: as per standard test methods or
better
Data Storage: 60,000 analyses.
ELECTRICAL
SPECIFICATION:
115V ± 15% / 60Hz 220V ± 15% / 50 to 60Hz
Shipping Weight: 267 lbs (121.1 kg)
Dimensions: 32x30x43 in. (81.3x76.2x109.2 cm)