TOC-VWS/VWP

Availablity: In stock

Catalog/Part Number: TOC-VWS/VWP
Brand: SHIMADZU
Supplier: SHIMADZU
Supplier Location: JAPAN
Inventory Weight: unavailable
Unit of Measurement:
Inventory Brochure: unavailable

Catalog/Part Number:: TOC-VWS/VWP

Sorry no inventory found for this brand at this time.

Description

TOC-V wet type series have a high-sensitivity NDIR which achieves ultrahigh sensitivity measurements. Sensitivity and accuracy enhanced by minimizing the reagent blanks that hinder accurate analysis. Powerful oxidation through a combination of peroxosulfuric acid, UV illumination, and heating.

Catalog/Part Number: TOC-VWS/VWP Category:

Technical Specifications

Automatic setting of optimal measurement conditions
When creating the calibration curve, the optimal measurement conditions are displayed when
 the standard solution concentration is set.
 Detailed calibration curve information can easily be referenced when setting the measurement conditions.
Automatic condition changing and re-analysis of out-of-range samples
If the sample peak goes over the calibration curve range, measurement conditions such as dilution
 rate and injection volume are automatically changed and the analysis is repeated.
Automatic selection of the best calibration curve
Up to three calibration curves can be set for sample measurement. The optimal calibration curve is
 selected for the sample and the sample measurements are conducted using these measurement conditions.
Automatic exclusion of anomalous values and re-calculation of repeated analyses
The mean value, standard deviation, and coefficient of variation are displayed and printed during 
repeated analyses. Anomalous values can be automatically eliminated and re-calculated.
Convenient automatic power off function
Automatic power off after electric furnance cools down ensures power is not left on and saves energy.
Comprehensive calibration system handles many uses:
Calibration curve can be created to compensate for TC in water used for standard solution adjustment.
A maximum of 25 (model S. model P has no limit) calibration curves can be stored and recalled. 
All calibration curve data can be displayed and recorded.
Automatic setting of optimal measurement conditions
When creating the calibration curve, the optimal measurement conditions are displayed when the 
standard solution concentration is set.
Detailed calibration curve information can easily be referenced when setting the measurement conditions.
Automatic condition changing and re-analysis of out-of-range samples
If the sample peak goes over the calibration curve range, measurement conditions such as dilution rate and 
Automatic selection of the best calibration curve
Up to three calibration curves can be set for sample measurement. The optimal calibration curve is selected for the sample and the sample measurements are conducted using these measurement conditions.
Automatic exclusion of anomalous values and re-calculation of repeated analyses
The mean value, standard deviation, and coefficient of variation are displayed and printed during repeated analyses.
Anomalous values can be automatically eliminated and re-calculated.
Convenient automatic power off function
Automatic power off after electric furnance cools down ensures power is not left on and saves energy.
Comprehensive calibration system handles many uses
Calibration curve can be created to compensate for TC in water used for standard solution adjustment.
A maximum of 25 (model S. model P has no limit) calibration curves can be stored and recalled. All calibration curve data can be displayed and recorded.