TOC-VWS/VWP
Catalog/Part Number:: TOC-VWS/VWP
Description
TOC-V wet type series have a high-sensitivity NDIR which achieves ultrahigh sensitivity measurements. Sensitivity and accuracy enhanced by minimizing the reagent blanks that hinder accurate analysis. Powerful oxidation through a combination of peroxosulfuric acid, UV illumination, and heating.
Technical Specifications
| Automatic setting of optimal measurement conditions |
| When creating the calibration curve, the optimal measurement conditions are displayed when |
| the standard solution concentration is set. |
| Detailed calibration curve information can easily be referenced when setting the measurement conditions. |
| Automatic condition changing and re-analysis of out-of-range samples |
| If the sample peak goes over the calibration curve range, measurement conditions such as dilution |
| rate and injection volume are automatically changed and the analysis is repeated. |
| Automatic selection of the best calibration curve |
| Up to three calibration curves can be set for sample measurement. The optimal calibration curve is |
| selected for the sample and the sample measurements are conducted using these measurement conditions. |
| Automatic exclusion of anomalous values and re-calculation of repeated analyses |
| The mean value, standard deviation, and coefficient of variation are displayed and printed during |
| repeated analyses. Anomalous values can be automatically eliminated and re-calculated. |
| Convenient automatic power off function |
| Automatic power off after electric furnance cools down ensures power is not left on and saves energy. |
| Comprehensive calibration system handles many uses: |
| Calibration curve can be created to compensate for TC in water used for standard solution adjustment. |
| A maximum of 25 (model S. model P has no limit) calibration curves can be stored and recalled. |
| All calibration curve data can be displayed and recorded. |
| Automatic setting of optimal measurement conditions |
| When creating the calibration curve, the optimal measurement conditions are displayed when the |
| standard solution concentration is set. |
| Detailed calibration curve information can easily be referenced when setting the measurement conditions. |
| Automatic condition changing and re-analysis of out-of-range samples |
| If the sample peak goes over the calibration curve range, measurement conditions such as dilution rate and |
| Automatic selection of the best calibration curve |
| Up to three calibration curves can be set for sample measurement. The optimal calibration curve is selected for the sample and the sample measurements are conducted using these measurement conditions. |
| Automatic exclusion of anomalous values and re-calculation of repeated analyses |
| The mean value, standard deviation, and coefficient of variation are displayed and printed during repeated analyses. |
| Anomalous values can be automatically eliminated and re-calculated. |
| Convenient automatic power off function |
| Automatic power off after electric furnance cools down ensures power is not left on and saves energy. |
| Comprehensive calibration system handles many uses |
| Calibration curve can be created to compensate for TC in water used for standard solution adjustment. |
| A maximum of 25 (model S. model P has no limit) calibration curves can be stored and recalled. All calibration curve data can be displayed and recorded. |