UV-1900i UV Vis Spectrophotometer

Availablity: EXW

Catalog/Part Number: UV-1900i
Brand: SHIMADZU
Supplier: SHIMADZU
Supplier Location: JAPAN
Inventory Weight: 20 kg
Unit of Measurement:
Inventory Brochure: 1567597874.pdf |

Catalog/Part Number:: UV-1900i

Description

The UV-1900i is a double-beam UV-Vis Spectrophotometer using Shimadzu's original LO-RAY-LIGH™ diffraction grating technology. In addition to its high optical performance, the UV-1900i features high resolution, low stray light, high reproducibility, and an ultra-fast scan function. It also has an easy-to-use interface on a color touch-screen display. The UV-1900i is designed to meet the needs of both high performance and usability.

The instrument is equipped with an ultra high-speed scan, which can acquire a spectrum in a few seconds, with the lowest level of stray light and noise in its class.

In quantitation mode on the UV-1900i, the stages of the entire measurement process and the current status are always shown on the display. As a result, users know immediately what to do in the next step.


" autofocus>

The UV-1900i is a double-beam UV-Vis Spectrophotometer using Shimadzu's original LO-RAY-LIGH™ diffraction grating technology. In addition to its high optical performance, the UV-1900i features high resolution, low stray light, high reproducibility, and an ultra-fast scan function. It also has an easy-to-use interface on a color touch-screen display. The UV-1900i is designed to meet the needs of both high performance and usability.

The instrument is equipped with an ultra high-speed scan, which can acquire a spectrum in a few seconds, with the lowest level of stray light and noise in its class.

In quantitation mode on the UV-1900i, the stages of the entire measurement process and the current status are always shown on the display. As a result, users know immediately what to do in the next step.


Catalog/Part Number: UV-1900i Category:

Technical Specifications


Wavelength range  
190 to 1,100 nm
Spectral bandwidth  
1 nm (190 to 1,100 nm)
Wavelength setting
0.1 nm increments (1 nm increments when setting scanning range)
Wavelength accuracy

± 0.1 nm at D2 peak 656.1 nm

 ± 0.3 nm for entire range

Wavelength repeatability
 ± 0.1 nm
Wavelength slew rate
 Approx. 29,000 nm/min
Wavelength scanning speed

3,000 to 2 nm/min

29,000 nm/min when survey scanning

Lamp interchange wavelength 

Automatic interchange linked to wavelength.

The interchange wavelength can be set freely in the range of 295 to 364 nm (0.1 nm increments).

Stray light 

 Less than 0.02% at 220 nm (NaI)

Less than 0.02% at 340 nm (NaNO2)

Less than 0.5% at 198 nm (KCl)

Photometric system
Double beam optics


https://shimadzugroup.sharepoint.com/sites/gcs/an_sales/Literature/Distributor/MolecularSpectroscopy/UV/c101e160.pdf