Availablity: In stock
Pensky-Martens Closed Cup Flash Tester
Catalog/Part Number:: K16273
Description
Test Method
For flash point determinations of
fuels, lubricating oils, liquids containing suspended solids and liquids that
tend to form a surface film during testing.
Features
Conforms to ASTM D93 and related
specifications
Choice of electric or gas heating
Description
Determines flash points of a wide
range of products by a closed cup method with two option speed stirring of the
sample. Extensively used in shipping and safety regulations for detection of
contamination by volatile and flammable materials in fuel oils and lubricating
oils, and for characterization of hazardous waste samples. Smooth operating
cover mechanism slides shutter open and applies test flame at the turn of a
knob. Cover fits over brass test cup and includes pilot flame, test flame reference
bead, built-in stirrer and plated brass thermometer ferrule. Electrically
heated model is equipped with a 1000W nickel-chromium heater with stepless
variable control for accurate, repeatable temperature rate of rise settings per
specifications. Heater unit is enclosed in a stainless steel housing with
cooling vents. Includes line cord receptacle and switch for accessory slow
speed stirrer. Gas heated model has a built-in nickel plated brass natural gas
burner, or can be supplied with an artificial gas burner or liquid propane
burner (specify when ordering). Both models are mounted on a sturdy cast iron
base.
Included Accessories
Brass Test Cup with Handle
Thermometer Holder
Cover Assembly
Test Method
For flash point determinations of
fuels, lubricating oils, liquids containing suspended solids and liquids that
tend to form a surface film during testing.
Features
Conforms to ASTM D93 and related
specifications
Choice of electric or gas heating
Description
Determines flash points of a wide
range of products by a closed cup method with two option speed stirring of the
sample. Extensively used in shipping and safety regulations for detection of
contamination by volatile and flammable materials in fuel oils and lubricating
oils, and for characterization of hazardous waste samples. Smooth operating
cover mechanism slides shutter open and applies test flame at the turn of a
knob. Cover fits over brass test cup and includes pilot flame, test flame reference
bead, built-in stirrer and plated brass thermometer ferrule. Electrically
heated model is equipped with a 1000W nickel-chromium heater with stepless
variable control for accurate, repeatable temperature rate of rise settings per
specifications. Heater unit is enclosed in a stainless steel housing with
cooling vents. Includes line cord receptacle and switch for accessory slow
speed stirrer. Gas heated model has a built-in nickel plated brass natural gas
burner, or can be supplied with an artificial gas burner or liquid propane
burner (specify when ordering). Both models are mounted on a sturdy cast iron
base.
Included Accessories
Brass Test Cup with Handle
Thermometer Holder
Cover Assembly
Technical Specifications
Specifications
Conforms to the specifications
of:
ASTM D93; AASHTO T73-811; IP 34;
ISO 2719; DIN 51758; FTM 791-1102; NF M 07-019
Electrical Requirements
115V 60Hz, Single Phase, 6.5A
220-240V 50/60Hz, Single Phase,
3.4A
Dimensions
lxwxh,in.(cm): 9.5 x8x22.5
(24x20x57) with optional stirrer motor installed
Net Weight: 25 lbs (11.4 kg)
K16225 Stirrer Motor, 115/230V
50/60Hz - Slow speed gear motor rotates stirrer of Pensky-Martens Tester at
105rpm for Procedure A and at 250rpm for Procedure B. Includes adjustable
support bracket and mounting rod. Installs in base of flash tester.
250-000-09F ASTM 9F Thermometer -
Range: 20 to 230°F
250-000-09C ASTM 9C Thermometer -
Range: –5 to +110°C
250-000-10F ASTM 10F Thermometer
- Range: 200 to 700°F
250-000-10C ASTM 10C Thermometer
- Range: 90 to 370°C
K16010 Cover Assembly - Complete
assembly. Includes shutter, flame exposure device, stirrer and thermometer
ferrule.
K16020 Brass Test Cup - With heat
resistant handle.
K16020-NI Nickel Plated Test Cup
- With heat resistant handle
Zero(0) Reviews