Test Method

For determination of Total Acid Number (TAN), Total Base Number (TBN), Mercaptan Sulfur and Karl Fischer Water Content of petroleum products, lubricants and transformer insulating oils. Titration is the fundamental chemical analysis procedure whereby the concentration of a chemical substance in solution is determined by reacting it with a measured amount of another chemical. The Auto titrator performs this analysis using a motor driven dispenser, stirred reaction vessel and electrodes which sense the completion of reaction by measuring the potential difference between two electrodes. Automatic Titration increases accuracy, repeatability, and reproducibility as well as minimizing errors in calculation and documentation.

 

Features

Acid-base or aqueous titration

Redox titration

Complexometric titration or EDTA titration

 Blank titration

Silver Assay titrations

Non-aqueous titration

Argentometric or Precipitation titration

Voltametric / KF Titration

Back titration

Description

The Automatic Titrator is provided with two-point auto calibration and standardization (zero offset). The instrument is capable of displaying pH and mV of the sample, with temperature compensation. The Automatic Titrator can accept a variety of electrodes to cater to various applications in different fields. The liquid path is comprised of Teflon tubing, a Teflon lined valve and gas tight burette with a Teflon plunger head. It creates a chemically inert system for any sensitive analysis. The instrument is supplied with high speed vortex stirrer with digital speed indication. This specially designed stirrer provides excellent homogenous mixing of samples. An optional magnetic stirrer is also available

Catalog/Part Number: K90500 Category:

Technical Specifications

Specifications

Conforms to the Specifications of:

ASTM D664, D2896, D3227, D4739

Principle: Volume determination by equivalence point, end point or pH STAT.

Control: Microcontroller based

mV range: ± 3200 mV.

AcCuracy: ± 0.1 mV (± 0.0016 pH).

Amplifier input impedance: > 10 ohms

Burette Resolution: 1/5000 for 5 ml, 1/10000 for 10 ml, 1/5000 for 25 ml.

Filling time: Less than 20 second

Keyboard: Alphanumeric splash waterproof polyester soft keys.

Display: 40 x 2 line back lighted liquid crystal display (LCD).

Titration Head: Manual stand with swiveling arm.

Stirrer System: Microcontroller based variable speed, high torque vortex stirrer with digital indication. (Magnetic Stirrer optional)

Sensors: Electrodes for Potentiometric titration - (pH, Ion, Redox, Argentometric).

        a) Any combination electrode.

        b) Differential Electrode System comprising sensing (Indicator) Electrode with BNC Connector and Reference Electrode with 4mm Banana Connector. Electrode for KF/Voltametric titration with BNC/TNC Connectors.

Temperature sensor (PRT/PT100) Calibration: 3-point Calibration with user entered buffer values and standardization with 7 pH buffer.

End Point detection:

        a) Potentiometric

        b) Voltametric

        c) Thermometric and Photometric.

Cut-off criteria:

        a) Volume

        b) End point

        c) mV/pH.

Methods:

Titrations:

        a) Acid base

        b) Nonaqueous

        c) Redox

        d) Preciptiation

        e) Complexometric

        f) back titration

KF titration (Optional)

Results:

        a) Molarity

        b) % Assay(wt),

        c) % volume (ml)

        d) ppm

        e) mg/l

        f)mg/g

        g)g/l

        h) meq/l

        i) mol/kg

        j) TAN and TBN for oil samples.

Method Storage: 50 methods with parameters.

Titrant Molarity storage: 20 values

Input/Output Peripheral Interface:

                (a) Parallel Port: 1 - for printer

                (b) Serial Port: 2 - for Balance & PC

Electrical Requirements

85 to 260 VAC; 48 to 62 Hz

 

Dimensions

wxdxh,in.(cm): 12x16x16(30.48x40.64x40.64)

 

Additional Accessories

K90500-1 Karl Fischer Titrator Burette Assembly

K90500-2 Filter Desiccant Dryer Tube

K90500-3 Magnetic Stirrer with Holding Ring

K90500-4 Magnetic Stirrer with Electrode Arm

K90500-5 Vessel Heating / Cooling Accessory

K90500-6 pH Checker