GC-2025

Availablity: In stock

Catalog/Part Number: GC-2025
Brand: SHIMADZU
Supplier: SHIMADZU
Supplier Location: JAPAN
Inventory Weight: unavailable
Unit of Measurement:
Inventory Brochure: 1568116828.pdf |

Catalog/Part Number:: GC-2025

Sorry no inventory found for this brand at this time.

Description

Shimadzu's new-generation GC-2025 capillary gas chromatograph minimizes environmental impact by reducing power and carrier gas consumption while retaining the performance capabilities required for capillary analysis.The GC-2025 incorporates a digital flow controller that controls both the carrier and detector gases and a newly designed energy-saving column oven that features small volume and less heating loss, realizing a dramatic improvement in operation costs.The compact GC-2025 is the gas chromatograph for environmentally friendly, high value performance.
FEATURES:
1) Eco-Friendly- The eco-friendly GC-2025 significantly cuts electric power costs compared to previous models to reduce the burden on the environment.Heat losses are significantly reduced through high-performance insulation and a smaller oven size to reduce the heating requirements. In addition, it incorporates an energy-saving heater to further cut power costs.Power consumption is reduced by 30% for programmed temperature analysis in comparison to other GC models.
2) Compact, All-in-One Design                                                                                                         Units for Normal Analysis Crowded into a Compact Space: The split/splitless injection unit (SPL), flame ionization detector (FID), and electronic flow controllers (AFC/APC) are installed as standard.                                              Compact Design Accepts Commercial Capillary Columns: Despite the compact instrument design, the small-capacity oven accommodates the shape of commercially available capillary columns (column depth 9 cm max.).
3) Incorporating design elements from the high-performance GC-2010 Plus capillary gas chromatograph, the GC-2025 achieves energy savings while offering the highest performance demanded for capillary analysis, delivering highly accurate analysis results and enhanced productivity.
4) High-Sensitivity Trace Analysis: The FID minimum detectable limit of 2 pgC/s offers high sensitivity for trace analysis.
5) Electronic Flow Controllers Achieve Excellent Operability and Reproducibility: The GC-2025 adopts the same well-proven electronic flow controllers (AFC/APC) for carrier gas and detector gas control that are used in the GC-2010 Plus. They offer highly accurate flow control to achieve excellent reproducibility.

Catalog/Part Number: GC-2025 Category:

Technical Specifications

No specification for this product

Add a review

You must login to make reviewLogin

  1. Zero(0) Reviews